New Original Antminer S21 XP Hashboard from Antminer S21 XP 270T with 91pcs BM1370 Asic Chip Without Heat sink
The Antminer S21 XP Hashboard does not include a heatsink. If you require hashboards with heatsinks, please order here: S21 XP Hashboard with Heat sink
|Техникалық сипаттамалар
Өнімге шолу
Value
Үлгі
S21 XP
Sub
270
Version
10
Crypto algorithm/coins
SHA256 | BTC/BCH/BSV
Typical hashrate,TH/s(1-1)
270
Power on wall @25℃(1-2), Watt(1-1)
3645
Power efficiency on wall@25℃(1-2),J/TH(1-1)
13.5
Егжей-тегжейлі сипаттамалар
Value
Power supply
Phase
1
Power supply AC input voltage(2-1) , Volt
220~277
Power supply AC input frequency range, Hz
50~60
Power supply AC input current(2-2), Amp
20
Hardware Ronfiguration
Network connection mode
RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm
450*219*293
Server size (length*width*height, with package), mm
630*350*430
Net weight, kg
18.7
Gross weight, kg
21.5
Шу(2-3)@30℃, dBA
76
Max airflow(2-4), CFM
480
Қоршаған ортаға қойылатын талаптар
Operation temperature, ℃
-20~45
Storage temperature, ℃
-20~70
Operation humidity(no condensation), RH
10%~90%
Operation altitude(2-5), m
≤2000
Notes:
(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet air temperature.
(2-1) Caution: Wrong input voltage may probably cause server damaged.
(2-2) Single-phase AC input 20A. (2-3) Max condition: Fan is under max RPM(rotation per minute). (2-4) When the server is dusty or the environment is poorly ventilated, the server airflow will reduce. (2-5) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.
New Original Antminer S21 XP Hashboard
$1,700.00
Antminer S21 XP Hashboard without Heat sink
Сипаттама
New Original Antminer S21 XP Hashboard from Antminer S21 XP 270T with 91pcs BM1370 Asic Chip Without Heat sink
The Antminer S21 XP Hashboard does not include a heatsink. If you require hashboards with heatsinks, please order here: S21 XP Hashboard with Heat sink
| Техникалық сипаттамалар
Notes:
(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet air temperature.
(2-1) Caution: Wrong input voltage may probably cause server damaged.
(2-2) Single-phase AC input 20A.
(2-3) Max condition: Fan is under max RPM(rotation per minute).
(2-4) When the server is dusty or the environment is poorly ventilated, the server airflow will reduce.
(2-5) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.
Сізге де ұнауы мүмкін…
MARTECH 12V 4.5A 7000RPM Cooling Fan for Antminer L9
$9.90Бастапқы бағасы: $9.90.$9.50Ағымдағы бағасы: $9.50. Себетке қосуS21XP Power Module
$2.90 Себетке қосуҚосымша тауарлар
S19XP Repair
$0.50 – $245.00Price range: $0.50 through $245.00 View productsStock CV1835 control board for S19j pro+
$35.00 Себетке қосуS21/S19j XP/KS5 үшін APW17 APW171215a
$375.00 Себетке қосуStock CV1835 control board for Antminer T21
$35.00 Себетке қосу